Hoshizaki HS-0243, 25' Tubing Kit Line Set for SRK-20H & SRK-20H3 Ice Machine Condenser, Brazing Required
$405.00Ā /ea
Hoshizaki HS-0243 Overview
Line Set for Hoshizaki Ice Machine Details:
You're on your way to making sure that you have it in you to put together the right kind of options in terms of getting hold of all of your options and ideas. If you want to put the time and effort into the right places, than this Hoshizaki HS-0243 line kit is the best option around to make your select ice maker and remote condenser have the right cohesion. This remote line set is going to work seamlessly with your air condenser for your ice machine so that you can see that your investment is going to be well worth the money and the options that you are waiting for.
Also, this ice machine and condenser line set is going to determine you success in terms of its energy efficiency and savings, so make sure you choose this to help you get to success faster and easier.
Requirements:
All KMS Serenity Series
- The maximum line set length is 66 feet. No refrigerant charge adjustment is necessary.
- The maximum vertical distance between the remote condensing unit and icemaker is 33 feet above or 10 feet below the icemaker. These distances are measured fitting to fitting.
- If the vertical distance between the remote condensing unit and the icemaker is greater than 20 feet (not to exceed 33 feet), an "S" oil-trap (5/8" OD tubing) must be installed in the suction line. The "S" oil-trap must be located halfway between the icemaker and remote condensing unit. This ensures sufficient oil return to the compressor.
- KMS-822, KMS-830 and KMS-2000 are brazed line set connections.
All Flaker Serenity Series
- The maximum line set length is 55' (17 m). No refrigerant charge adjustment is necessary.
- The maximum vertical distance between the remote condensing unit and icemaker is 33' (10 m) above or 10' (3 m) below the icemaker. These distances are measured fitting to fitting.
- If the vertical distance between the remote condensing unit and the icemaker is greater than 20' (6 m) (not to exceed 33' (10 m)), an "S" oil-trap (5/8" OD copper tubing) must be installed in the suction line. The "S" oil-trap must be located halfway between the icemaker and remote condensing unit. This ensures sufficient oil return to the compressor.
Note: Hoshizaki recommends that all new remote installations should include a new condenser and line set. The use of existing condensers is not recommended/allowed as they may not provide for optimum performance and could affect the refrigeration system warranty coverage.