Hoshizaki HS-0250, 25' Tubing Kit Line Set for SRK-8H, SRK-8H3 & SRK-10H Ice Machine Condenser, Brazing Required
$390.00Ā /ea
Hoshizaki HS-0250 Overview
Line Set for Hoshizaki Ice Machine Details:
You wouldn't put an old tire on a new car, so make sure that you treat your brand new air condenser with the same respect. Put only new refrigeration tubing in place when you are looking at putting together the right kind of package in terms of your overall quality. You are going to be able to see that this Hoshizaki HS-0250 ice machine remote condenser line set will give you the right traits for quality purchase as well as the guarantee that you are going to be able to enjoy the knowledge that you are doing what you have to do long term too.
Don't settle for inferior quality by using old and new equipment together. When you replace one, replace both! You'll be happy you chose to do that with this line set combined with your new ice machine.
Requirements:
All KMS Serenity Series
- The maximum line set length is 66 feet. No refrigerant charge adjustment is necessary.
- The maximum vertical distance between the remote condensing unit and icemaker is 33 feet above or 10 feet below the icemaker. These distances are measured fitting to fitting.
- If the vertical distance between the remote condensing unit and the icemaker is greater than 20 feet (not to exceed 33 feet), an "S" oil-trap (5/8" OD tubing) must be installed in the suction line. The "S" oil-trap must be located halfway between the icemaker and remote condensing unit. This ensures sufficient oil return to the compressor.
- KMS-822, KMS-830 and KMS-2000 are brazed line set connections.
All Flaker Serenity Series
- The maximum line set length is 55' (17 m). No refrigerant charge adjustment is necessary.
- The maximum vertical distance between the remote condensing unit and icemaker is 33' (10 m) above or 10' (3 m) below the icemaker. These distances are measured fitting to fitting.
- If the vertical distance between the remote condensing unit and the icemaker is greater than 20' (6 m) (not to exceed 33' (10 m)), an "S" oil-trap (5/8" OD copper tubing) must be installed in the suction line. The "S" oil-trap must be located halfway between the icemaker and remote condensing unit. This ensures sufficient oil return to the compressor.
Note: Hoshizaki recommends that all new remote installations should include a new condenser and line set. The use of existing condensers is not recommended/allowed as they may not provide for optimum performance and could affect the refrigeration system warranty coverage.
WARNING: This product can expose you to chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. For more information go to ā www.P65Warnings.ca.gov
Hoshizaki HS-0250 Specifications